Key Features
- Standard IEC 60320 C20 plug to C15 connector
- Blue jacket for easy identification of redundant power paths
- C15 connector is backwards compatible — mates with both C14 and C16 inlets
- C15 rated for higher-temperature applications (up to 120°C) compared to standard C13
- Rated for 15 Amps, 250 Volts AC
- 0.9 Meters / 3 Feet cord length
Documentation
- Technical Drawing
- Certificate of Compliance
- Certificate of Origin
- REACH Compliance
- RoHS Compliance
- Prop 65 Declaration
- WEEE Compliance
- Product Lifecycle Statement
- ISO 9001:2015 QMS Certificate
Specifications
| Male Plug | IEC60320 C20 |
| Female Connector | IEC60320 C15 |
| Length | 0.9 Meters / 3 Feet |
| Amperage | 15 Amps |
| Voltage | 250 Volts |
| Gauge | 14 AWG |
| Conductors | 3 Wire |
| Conductor Color Code | Black, White, and Green | North American Color Code (NACC) |
| Outside Diameter | 9.15 - 9.45 mm |
| Packaging | Loose and bundled. |
| Jacket | SJT |
| Jacket Material | PVC |
| Jacket Temp. Rating | 105° C |
| Color | Blue |
| Testing | Each cord is tested for dielectric voltage-withstand (Hi-Pot), polarization and continuity. |
| Certifications | UL/cUL Listed |
Application Notes
IEC 60320 C20 to C15 Blue power cords connect a 20-amp PDU outlet to equipment with a C14 or C16 inlet, combining the C15 connector's 120°C temperature rating with color-coded jacket identification. The C15 is backwards compatible with both C14 and C16 inlets, providing flexibility across a wide range of devices — from standard servers using C14 inlets to high-temperature equipment designed for C16.
Color-coded cords simplify the identification of redundant power paths in data center and server rack environments. Using Blue cords for a dedicated power feed allows operations teams to verify dual-feed connections and trace circuits at a glance, reducing the risk of accidental disconnects during rack servicing.
C20 to C15 Blue cords are ideal for data centers and colocation facilities where high-temperature-rated connectivity and clear power path identification are both required.
Product FAQs
What is the difference between a C13 and a C15 connector?
Both C13 and C15 are IEC 60320 connectors, but the C15 is rated for higher-temperature applications — up to 120°C compared to 70°C for the C13. The C15 is also backwards compatible, meaning it mates with both C14 and C16 inlets. It is the preferred connector for equipment that runs hot or is specifically designed for high-temperature operation.
Is the C15 connector backwards compatible with C14 inlets?
Yes. The C15 connector is designed to mate with both C14 and C16 inlets. This makes C20-to-C15 cords suitable for a wide range of equipment, including devices with either inlet type, without requiring separate cord SKUs for each.
Why use Blue power cords?
Color-coded power cords make it easy to identify redundant power paths at a glance. Using Blue cords for a specific power feed helps data center and operations teams quickly trace circuits, verify dual-feed connections, and reduce the risk of accidental disconnects during rack servicing.
Why use a C20 plug with a C15 connector?
A C20-to-C15 cord allows you to power high-temperature-rated equipment directly from a 20-amp PDU outlet. This combination is common in data centers where PDUs are wired with 20-amp circuits and the equipment requires the elevated temperature rating of the C15 connector.